MONITORING OF A MULTI-STOREY CAR PARK

Structural monitoring of underground car parks and multi-storey car parks

Monitoring of corrosion and moisture in multi-storey car parks

As a result of high repair costs for existing multi-storey car parks, the city administration has already decided to install moisture and corrosion sensors in the new building. The reason for this is not only the early detection of damage but also the monitoring of the building until VOB acceptance and beyond.

Due to the special construction method (built-over roof of the underground car park), particular importance was attached to moisture monitoring, as the sealing of the roof surface is not accessible. Therefore, moisture sensors were to be installed, among other things, in the low drainage point of the car park ceiling and in the drainage joints of the entrance ramps.

Install corrosion sensors (standard version) in the supports of the parking decks and at the most frequented parking spaces.

Überwachung von Parkhäusern auf Feuchtigkeit

The data was read out manually using a handheld reader. Alternatively, a fully automatic remote readout is also available.

Monitoring of a car park with Corrodec2G

The added value of monitoring for moisture & corrosion with Corrodec2G

Our solutions for monitoring multi-storey & underground car parks