Leak detection cable for leak detection

The leak detection cable (water sensing cable) reports water as soon as it touches the cable. It is laid along the at-risk areas, without drilling into the fabric of the building, and triggers an automatic alert via the gateway.

  • Up to 40 m length
  • No structural intervention
  • Alert via SMS and email
Leak detection cable connected to an Infrasolute gateway on a wet floor area, the alarm LED is lit red

Why the leak detection cable

Water is detected where it comes out

A point water detector sees one spot. The leak detection cable sees its entire length, and that length can be laid exactly where a leak is likely to occur.

Sensitive along the full length

Not a single point, but the entire laid stretch. Under washing machines, along heating systems or along walls.

No structural intervention

The cable is rolled out, not built in. No drilling, no tradesman, no intervention in the fabric of the building.

Reacts immediately

When the cable touches water, its electrical resistance changes. The system registers the change within milliseconds.

Alerts automatically

The gateway triggers an SMS or email without any further action, before a leak turns into damage.

Damage can be localised

After an alert, a simple manual measurement on the cable identifies the area where the water sits.

Custom designs also available

Several zones can be connected to a central gateway, on request fully cabled and with a display.

Technical data

Specifications at a glance

Measured quantity
Water contact along the entire cable length
Diameter
0.5 cm
Temperature range
0 to 80 °C
Measuring principle
change in electrical resistance on water contact
Maximum length
usually up to 40 m
Extension
not via plug connectors; the lead to the gateway can be extended with normal cable
Installation
rolled out, without structural measures
Readout
gateway available with mains power or battery
Alerting
automatic via SMS and email
Localisation
manual remeasurement on the cable narrows down the area
Laid leak detection cable on a floor surface, next to the layer structure with the cable inside the screed

Operating principle

Three steps from water to notification

The cable is the core, the gateway handles the evaluation. It is laid along the locations where water could escape, in the screed, in insulation material or openly on the floor.

  1. 01

    Detection

    As soon as the cable comes into contact with water, its electrical resistance changes.

  2. 02

    Recognition

    The system registers this change within milliseconds.

  3. 03

    Alerting

    You receive an SMS or email immediately, before serious damage occurs.

The difference

Point detector versus leak detection cable

Point water detector

  • Detects water only at the one spot where it sits
  • If water passes by, it reports nothing
  • A whole area needs many devices
  • The affected area cannot be narrowed down

Leak detection cable from Infrasolute

  • Sensitive along the entire laid length
  • Follows the course of the at-risk areas
  • Up to 40 m on one gateway, several zones possible
  • After an alert, a measurement on the cable narrows the area

Applications

Where the leak detection cable is laid

Basements and underground car parks
Plant rooms
On the screed
In insulation material
Multi-family buildings

Everything from a single source

From the monitoring concept to operation

The leak detection cable is one building block of well-designed monitoring. On request, Infrasolute takes care of concept, installation, operation and ongoing monitoring as a complete solution, a single point of contact for the whole monitoring.

  1. 01

    Concept

    We determine where the cable needs to run and where the gateway sits.

    Learn more
  2. 02

    Installation

    On request, we lay the leak detection cable and gateway professionally and commission everything.

    Learn more
  3. 03

    Maintenance and operation

    We keep cable, gateway and transmission operational.

    Learn more
  4. 04

    Monitoring and alerting

    We watch the notifications and forward every alert to the responsible party.

    Learn more

Which area do you want to protect?

Tell us about the rooms concerned. We will suggest the cable run and length and the right gateway version.

Benedikt Seuss Benedikt Seuss

Data platform

All readings on one platform

The sensors transmit their readings wirelessly to the data platform, where they are evaluated, documented and continuously checked against your thresholds.

  • AI-assisted data analysis
  • User-focused reporting
  • Continuous evaluation
  • Warning and alarm thresholds
  • Alerts by email and text message
  • Remote access around the clock
More on monitoring & alerting
Monitoring platform Sample view
Reading history within limits
Warning threshold
  • AI-assisted data analysis Condition within limits
  • User-focused reporting Report ready
  • Alerting Thresholds monitored
FAQ

Frequently asked questions about the leak detection cable

How long can the leak detection cable be?
The leak detection cable can usually be up to 40 m long. It cannot be extended via plug connectors. However, the connection from the leak detection cable to the gateway can be extended with normal cable.
How does the cable detect a water leak?
As soon as the cable comes into contact with water, its electrical resistance changes. The system registers this change within milliseconds and triggers an SMS or email notification via the gateway.
Does installation require drilling or chiselling?
No. The leak detection cable is rolled out on the floor or along the at-risk areas. No structural measures and no tradesmen are required.
Can I find out exactly where the water is sitting?
Yes, after the alert. A simple manual measurement on the cable identifies the area where the damage occurred. This narrows the search to one section instead of having to open the whole area.
Is a power connection required?
For the gateway, not for the cable. The gateway comes in two versions, with mains power or with a battery. Which one fits depends on whether a power socket is reachable at the installation site.
Can several areas be monitored together?
Yes. Custom designs are always possible, for example fully cabled systems with a built-in display, where cables from several zones are connected to a central gateway.

Project inquiry

Request the leak detection cable

Tell us which rooms or areas should be protected. We will suggest the cable run, length and the right gateway version.

+49 6742 8599600 DE +41 41 670 00 11 CH [email protected]
Project inquiry