The monitoring concept, before the first sensor sits
Before the first sensor is mounted, there is a solid monitoring concept. An individual concept for each structure, built on a standardised, scalable IoT platform. We plan so that every measuring point answers a question and every threshold triggers a decision.
- Concept free of charge
- Aligned with DIN 1076
- No commitment to operation
Full-service process
Planning before technology
Why a monitoring concept comes first
Monitoring is only as good as its planning. We therefore reverse the usual order: first the measuring task with its points and thresholds, then the technology that fits it. And we prepare the concept itself free of charge.
Request a quoteMeasuring task first
We clarify what needs to be measured, at which points and with which thresholds. Only then does the sensor selection follow.
Every point justified
For every position we document why measurement takes place there and what the reading allows you to conclude. No sensor without a purpose.
Manufacturer-independent
Where our sensors solve the task best, we recommend them. Where another solution makes more sense, we say so as well.
Economically planned
As lean as possible, as extensive as necessary. This keeps the initial investment and ongoing cost within a comprehensible frame.
Prepared free of charge
We do not invoice you for the concept. You receive an implementable monitoring concept and then decide freely whether to continue with us.
Process
Four steps to a solid monitoring concept
- 01
Enquiry and objective
You describe the structure, the damage pattern and the occasion to us. Together we define which question the monitoring should answer: proving crack growth, safeguarding structural stability or avoiding a closure.
- 02
Condition analysis
We review inspection reports to DIN 1076, structural documents and existing damage surveys. From this we derive the critical areas that need to be monitored.
- 03
Monitoring concept and measuring point planning
We select the suitable sensors, define measuring points, measuring intervals and warning and alarm thresholds, and describe how the data feeds back into your inspection cycles.
- 04
Quotation and implementation plan
You receive a concrete quotation with a parts list, mounting concept and schedule. On request, we take over mounting, commissioning and ongoing operation.
Sensor selection by measuring task
The monitoring concept planner
Choose a measuring task and see which sensors, which interval and which standard we apply for it. A simplified example, not a substitute for individual planning.
Active measuring points for the selected task
Recommendation from the concept
Crack growth
- Sensor
- Crack sensor (NB-IoT, autonomous)
- Measured quantity
- Crack width change in the hundredth-of-a-millimetre range
- Measuring interval
- weekly to every 3 minutes
- Assessment basis
- Structural assessment of the structure
Scope of service
What is included in the concept
At the end you hold an implementable monitoring concept: a measuring point plan, sensor selection, thresholds, intervals and a quotation with a parts list and schedule.
- Review of existing inspection and condition documents
- Selection of the suitable sensors for each measuring task
- Measuring point plan with a justification for every position
- Definition of warning and alarm thresholds
- Definition of measuring intervals and data pathways
- Integration into existing inspection cycles to DIN 1076
- Quotation with parts list, mounting and schedule
Which inspection types and deadlines DIN 1076 requires is explained in the knowledge article Bridge inspection to DIN 1076
Your result
You then decide freely whether to carry out the implementation internally or hand mounting and operation over to us. The concept is an independent service.
What a finished monitoring concept looks like in practice is shown by the reference projects. Sorted by structure type you will find them under bridges, car parks and parking garages and the remaining structure types.
Everything from a single source
From the monitoring concept to alerting, one point of contact
The concept is the first step of a continuous chain. On request, Infrasolute takes over every further step, without interfaces where responsibility gets lost.
Concept
Monitoring concept, sensor selection, measuring points and thresholds, aligned with DIN 1076.
You are hereInstallation
Wireless mounting of the sensors and commissioning with a documented baseline measurement.
Learn moreMaintenance and operation
Data platform, sensor maintenance and battery replacement as monitoring as a service.
Learn moreMonitoring and alerting
Ongoing evaluation with automatic alerting by email and SMS.
Learn moreWe start with the condition analysis
Describe your structure and the occasion to us. We review the documents and prepare an implementable monitoring concept free of charge.
Data platform
All readings on one platform
The sensors transmit their readings wirelessly to the data platform, where they are evaluated, documented and continuously checked against your thresholds.
- AI-assisted data analysis
- User-focused reporting
- Continuous evaluation
- Warning and alarm thresholds
- Alerts by email and text message
- Remote access around the clock
- AI-assisted data analysis Condition within limits
- User-focused reporting Report ready
- Alerting Thresholds monitored
Frequently asked questions
How does the concept differ from a pure sensor supply?
Does the concept take DIN 1076 into account?
How are warning and alarm thresholds defined?
Can I commission the concept without the later operation?
Which documents do you need from us for the concept?
What does a monitoring concept cost?
Is a monitoring concept worthwhile for new construction too?
How many measuring points does a structure need?
How long does it take to prepare a monitoring concept?
Project inquiry
Your monitoring concept starts here
Describe your structure, the damage pattern and the occasion to us. We clarify with you which measuring points and which thresholds fit your task.
+49 6742 8599600 DE +41 41 670 00 11 CH [email protected]