Detect corrosion before it becomes visible
Moisture and chlorides destroy concrete and reinforcement from the inside. With passive, energy-free CorroDec 2G sensors, you detect capillary moisture, chloride fronts and corrosion risk early enough to act in a targeted and cost-efficient way.
Why moisture and corrosion monitoring
Why moisture in the component is so dangerous
Concrete and steel form an economical and resilient combination, with one natural weak point: moisture and chlorides destroy the protective passive layer of the reinforcement steel over time. The damage develops unnoticed inside the structure, long before spalling and cracks become visible on the surface.
Request a quoteLoss of the passive layer
Chlorides and persistent moisture dissolve the corrosion-protective passive film on the reinforcement steel. The steel begins to rust, initially completely hidden.
Early warning instead of a refurbishment case
Once pitting, spalling and cracks become visible, the refurbishment effort is already considerable. Monitoring detects corrosion activity before it becomes a hazard.
Moisture trend in the concrete
The moisture sensor measures the electrical conductivity and temperature inside the component and delivers a reliable trend of how the moisture develops.
Chloride and corrosion risk
The corrosion sensor monitors, using a continuous sensor wire in two levels, whether corrosive influences reach the reinforcement steel.
Preserving the value of the asset
Whoever knows the condition can refurbish in a targeted and cost-efficient way instead of across the board. This sustainably protects the substance and the value of the structure.
Evidence and control
The monitoring documents the quality of a new build and objectively tracks the success of a repair over years.
Simulation
The moisture traffic light in the component
Follow how the capillary moisture moves into the concrete and the chloride front reaches the reinforcement steel. The traffic light shows the corrosion risk at every stage, exactly what the sensor captures in the real component.
Condition
Dry
No risk
The concrete is dry, the passive layer of the reinforcement steel is intact. Sensor wire level 1 and 2 are both in order.
How CorroDec 2G works
A passive, energy-free early warning system for concrete
The CorroDec 2G sensors are installed at the at-risk points of the structure, either during construction or retrofitted. They are passive and energy-free and have no cable connection to the outside. This ensures an extremely long service life and rules out harmful substances entering the structure along a cable. Only the reader supplies the sensor with energy when it is queried.
- 01
Corrosion sensor
A continuous sensor wire is destroyed by corrosive influences. Read out are wire level 1 in order yes or no, level 2 in order yes or no, and the temperature in the concrete.
- 02
Moisture sensor
Two stainless steel rings measure the electrical conductivity and temperature in the concrete and deliver a reliable trend of the moisture development.
- 03
RFID readout
The reader works on the RFID principle. In 3 to 5 seconds it delivers condition and readings, without any cable and without a battery in the sensor.
Technical data
- Read range
- Standard up to 10 cm, Advanced up to 45 cm
- External antenna
- Installation depths up to 100 m possible
- Concrete thickness
- Special versions up to 100 m
- Data storage
- up to 1,000 sensors in the reader
Offline on site
Readout with a handheld reader directly at the structure. The self-test evaluates condition and sensor wire fully automatically and documents the data via software.
Online 24/7
Through the system extension for remote readout, the data is transmitted via Narrowband (NB-IoT), visualised and an alert is triggered if a threshold is exceeded.
Installation variants
All technical details, installation variants and the inquiry flow for the passive moisture and corrosion sensor CorroDec 2G.
Stress corrosion cracking
Moisture and chloride are the precondition
Stress corrosion cracking (SCC) only occurs when two things come together: permanent tensile stress in the prestressing steel and a corrosive medium such as chloride or moisture. The second condition is the one that can be measured directly in the concrete, before it takes effect. The damage itself then proceeds inside the structure and only becomes visible through the deflection of the superstructure.
Everything from a single source
From the monitoring concept to ongoing operation
Infrasolute is a solution provider, not a parts supplier. You receive the entire moisture and corrosion monitoring from a single source, with one point of contact for the full term.
Concept
We determine measuring points, sensor types and installation variants to match the structure and the relevant standards.
Learn moreInstallation
Installation before concreting or retrofitted by core drilling, carried out correctly and sealed to standard.
Learn moreMaintenance and operation
We operate the system, check the sensors and keep the readout reliably functional on a lasting basis.
Learn moreMonitoring and alerting
Continuous evaluation of the readings and automatic alerting when a threshold is exceeded.
Learn moreMoisture & corrosion monitoring for your structure
Tell us which structure you want to monitor. We recommend the right sensors and measuring points and get back to you shortly with a no-obligation quote.
Data platform
All readings on one platform
The sensors transmit their readings wirelessly to the data platform, where they are evaluated, documented and continuously checked against your thresholds.
- AI-assisted data analysis
- User-focused reporting
- Continuous evaluation
- Warning and alarm thresholds
- Alerts by email and text message
- Remote access around the clock
- AI-assisted data analysis Condition within limits
- User-focused reporting Report ready
- Alerting Thresholds monitored
Applications
Where moisture and corrosion monitoring protects
Wherever chlorides, moisture and de-icing salt attack the concrete and the reinforcement, the monitoring delivers the decisive advantage.
- Car parks and underground car parks
- Bridges and prestressed concrete
- Tunnels and portals
- Water and port structures
- Flat roofs and roof structures
- Building construction and facades
- Sewage treatment plants under sulphate exposure
- Shaft and foundation structures
Related solutions
The right monitoring for every moisture question
Moisture and corrosion monitoring detects damage hidden inside the component. For active water leaks, for the construction phase and for the entire concrete structure there are matching complements.
Leak monitoring
Detects escaping water within seconds, using a leak detection cable with immediate alerting. For basements, screed and plant rooms rather than corrosion in concrete.
To leak monitoringConcrete monitoring
The overall package for concrete structures: moisture, corrosion, cracks and structural changes brought together in a single solution.
To concrete monitoringConcrete maturity monitoring
Temperature, maturity and strength in the fresh component, for the formwork-striking time. After that, continuous monitoring in the structure takes over.
To concrete maturity monitoringCase study
Project example as a PDF
What moisture and corrosion monitoring looks like in a real project: enter your name and email address and we will send you the case study.
Frequently asked questions
What is the difference between moisture monitoring and leak monitoring?
Can the sensors be installed retrospectively?
Do the sensors need power or a cable connection?
How are the sensors read out?
How deep in the concrete can the sensors sit?
Can this also be used to monitor stress corrosion cracking?
Project inquiry
Moisture & corrosion monitoring for your structure
Tell us which structure you want to monitor. We recommend the right sensors and measuring points and get back to you shortly with a no-obligation quote.
+49 6742 8599600 DE +41 41 670 00 11 CH [email protected]