Data centre monitoring: leaks, roof and access in view
Water under the raised floor, load on the roof, open manholes and doors: Infrasolute monitors the structural risks of a data centre with wireless sensors, retrofittable during operation, with alerts by SMS and email.
In a data centre, every minute of availability counts. Water under the raised floor, overload on the roof and an open cable manhole are three different risks. Infrasolute monitors them with one platform and one alarm chain.
Leak detection cables and water leak sensors report escaping water under the raised floor and in plant rooms immediately by SMS and email, around the clock.
Roof load measured, not estimated
The deflection of the roof structure is measured by laser. With snow, heavy rain or additional plant on the roof, the warning comes before the overload.
Every opening reported
The manhole sensor reports the opening of manhole covers, doors and gates the moment it happens, with location and time.
Separate from your network
The gateways transmit over the mobile network using their own SIM. No access to the data centre network is required.
Three areas
What is monitored in a data centre
Each area has its own sensors. The alerts come together on the same platform.
Leak monitoring
Detect water under the raised floor early
Chilled water pipes, condensate drains and the connections of the cooling units run under the raised floor. A leak there stays invisible for a long time. The leak detection cable is rolled out along these runs and reports water along its entire length, up to 40 m per cable. At known points, such as under a pump or at a drain, a water leak sensor is enough.
Data centres have large, often flat roofs that also carry dry coolers and plant. Snow, ponding water when drains are blocked and storms put additional load on the structure. Laser-based deflection measurement shows how much the roof deforms under the current load and raises an alarm when the defined limit states are reached. The gutter sensor on the roof gutter and downpipe records standing water, rainfall, moisture and temperature and reports a developing blockage before water backs up on the roof.
Deflection measured continuously
blocked gutters and downpipes reported, gutter sensor solar-powered
Thresholds defined together with you
retrofittable to existing roofs and readable remotely
Fibre and power reach a data centre through cable manholes on the site. If a cover is lifted or a door to a plant or ancillary room is opened, the manhole sensor reports it immediately. In the same manhole, a water level sensor measures whether water is standing.
Opening of covers, doors and gates reported immediately
battery powered, without cables or a power connection
The IT in the data hall monitors itself. The building around it needs its own sensors: where water can escape, where load acts on the structure and where someone can get in from outside.
Raised floor in the data hall
Under cooling units, along the chilled water pipes and at condensate drains.
Plant rooms
Chiller and pump rooms, boiler and utility connection rooms, with water leak sensors at known points of risk.
Roof structure
Deflection of the structure under snow, rain, wind and rooftop plant, plus gutters and downpipes with the gutter sensor.
Site and access points
Cable and fibre manholes, doors to ancillary and plant rooms, gates. Every opening is reported.
How it works
Four steps to the alert
Retrofitting takes place during operation, and transmission is separate from your IT.
01
Define the points of risk
Together with your operations team, we define where water can escape, which roof areas are measured and which access points should be reported.
02
Retrofit during operation
Leak detection cables are rolled out, sensors are mounted and the roof sensors are fixed to the load-bearing structure. No work on the building fabric and no shutdown are needed.
03
Transmit via own SIM
The gateways send to the Infrasolute platform over the mobile network, independently of the data centre network. With battery backup, they keep running during a local power failure.
04
Alert and integrate
Threshold exceedances go by SMS and email to the defined recipients, with escalation on request. Via an API, the readings can be passed to your control room.
Single source
From the monitoring concept to ongoing operation
From selecting the measuring points through installation to alerting, everything stays with one contact.
All measuring points of a data centre, and of several sites if required, on one overview map, with one alarm chain and a connection to your control room.
Frequently asked questions about data centre monitoring
Which risks in a data centre can be monitored with sensors?
Infrasolute monitors three areas in data centres: leaks under the raised floor and in plant rooms with leak detection cables and water leak sensors, the load on the roof using laser-based deflection measurement, gutters and downpipes with the gutter sensor, and the opening of cable manholes, doors and gates with the manhole sensor. All alerts come together on one platform with one alarm chain.
How do you detect a water leak under the raised floor?
With a leak detection cable laid under the raised floor along the chilled water pipes, condensate drains and cooling units. When the cable comes into contact with water, its electrical resistance changes and the system reports the leak immediately by SMS and email. A cable can generally be up to 40 m long.
Leak detection cable or water leak sensor: which fits in a data centre?
If water can escape along a run or over an area, for example under the raised floor, the leak detection cable is the right choice because it is sensitive along its entire length. At known points of risk such as a pump or a drain, one water leak sensor per point is enough. Both can be combined in one system.
Does the monitoring need access to the data centre network?
No. The gateways transmit to the Infrasolute platform over the mobile network using their own SIM. The data centre network is not used. The platform servers are located in Germany, and the system is developed and manufactured in Germany.
What happens during a power or network outage?
The gateways have battery backup and transmit over the mobile network. They therefore remain operational during a local power or Wi-Fi outage. The sensors for manholes and access points run on batteries anyway.
How is the roof load on a data centre monitored?
Instead of weighing the load, the system measures the deformation of the roof structure. Laser-based deflection measurement shows how much the roof deforms under snow, rain, wind and rooftop plant. When predefined limit states are reached, the system raises an alarm automatically.
How are the gutters and downpipes on a data centre monitored?
With the gutter sensor. It sits on the roof gutter and records standing water, rainfall, moisture and temperature at the same time. If rain falls without the expected pattern appearing in the gutter, the system detects a developing blockage and reports it before water backs up on the roof. The sensor is solar-powered, transmits via NB-IoT and needs no battery changes on the roof.
Can the system be retrofitted during operation?
Yes. Leak detection cables are laid, not built in; water leak and manhole sensors are mounted; the roof sensors are fixed to the existing structure. No shutdown and no work on the building fabric are needed.
Can the data be passed to our control room?
Yes. Via an API, the Infrasolute platform passes readings and alerts to existing monitoring systems, for example the control room. Dashboard, data export and reports by email are also available.