Strut monitoring in an excavation: how the monitoring works
Project facts
- Type
- Application example: typical procedure, not a single project
- Structure
- Excavation with retaining wall and pipe or rolled-section struts at one or more levels
- Task
- Record and assess the axial force in selected struts from installation to removal
- Measuring principle
- Strain in the steel with vibrating wire gauges, axial force from modulus of elasticity and cross-section
- In addition
- Tilt of the retaining wall, vibration at neighbouring buildings, water levels
Installed sensors
At a glance
- Type: application example showing the typical procedure, not a single project
- Structure: braced excavation with pipe or rolled-section struts at one or more levels
- Task: record the axial force in selected struts from installation to removal and check it against thresholds
- Sensors: vibrating wire strain gauges on the struts, plus tilt sensor, vibration sensor, water level sensor and groundwater sensor
- Result: the load in each monitored strut as a time series on the platform, with warning and alarm levels
Background
Struts carry the load you cannot see
In a braced excavation, the soil, often together with the groundwater, pushes against the retaining wall from outside. Walers collect this load and pass it to the struts, which brace the opposite walls against each other. How large the force in a strut actually is depends on the ground, the excavation level, the preload and the temperature. It cannot be seen from outside.
Strut monitoring makes this force measurable. It shows whether the struts behave as assumed in the design and reports when a strut takes more load than intended. This protects the excavation, neighbouring buildings and the people working in it.
Measuring principle
From strain in the steel to strut load
A vibrating wire strain gauge measures the change in length between two fixing points on the steel. If the strut is compressed further, the steel shortens, and the wire in the gauge changes its tension and therefore its frequency. The mean of the strains from all gauges in a section, multiplied by the modulus of elasticity and the cross-sectional area, gives the axial force. The differences between the gauges show whether the strut is also subject to bending.
Procedure
How strut monitoring works
- Plan the measuring sections: together with the structural and geotechnical engineers, it is decided which struts will be monitored, for example the most heavily loaded ones and struts in corners or close to sensitive neighbouring buildings. Warning and alarm levels are derived from the design for each monitored strut.
- Install the gauges: on pipe struts, usually three gauges are spaced at 120° around the circumference; on H and I sections, at least four, in pairs either side of the neutral axis. They are fitted at a distance from the strut ends, where the force flow is uniform. Where arc welding is not permitted, a spot-weldable version is available. A cover protects against direct sunlight and damage during construction.
- Zero reading: before the strut is loaded, the system records the initial state. All later readings refer to it.
- Preloading and excavation: the force rises sharply during preloading and continues to grow with every further excavation step. The platform shows the curve for each strut and level, so every construction step can be traced in the data.
- Construction stage: over days and weeks, a daily cycle appears. Struts restrained between the walls take on a real additional force as they warm up. The thermistor in each gauge makes this share visible.
- Warn and alert: when a strut reaches its warning level, a notification goes to the people responsible. At the alarm level, the measures agreed in advance take effect.
- Removal and report: when the struts are removed, the measurement shows how the load is redistributed. The end result is complete documentation of the strut loads over the entire construction period.
3 × 120°
gauges per pipe strut
≥ 4
gauges per H or I section
< 1 µε
resolution of the vibrating wire gauge
2 levels
warning and alarm level per strut
Overall system
Struts are one part of excavation monitoring
Strut load alone does not answer every question. If the retaining wall tilts while the strut loads remain normal, the cause may lie at the toe of the wall. If the groundwater rises, the pressure on the retaining wall increases. That is why all measured values from the excavation come together on the platform.
- Vibrating wire strain gauges on the struts: strut load per level
- Tilt sensor at the wall head: tilt of the retaining wall
- Vibration sensor at neighbouring buildings: vibration to DIN 4150-3
- Water level sensor in the pump sump: water level in the excavation
- Groundwater sensor in the standpipe: groundwater outside the excavation
The page Excavation monitoring explains how the components work together and which questions clients and site management should clarify in advance.
Benefits
What strut monitoring delivers
- Safety during construction: an overload shows up as a trend before it becomes critical. There is time to stop excavation or add bracing.
- Confirmation of the design: the measured forces show whether the design assumptions hold true and provide the basis for decisions under the observational method.
- Clear responsibilities: warning and alarm levels, recipients and measures are agreed in advance. Nobody has to improvise in an emergency.
- Documentation: the complete record of all strut loads is available for questions about neighbouring buildings or at acceptance.
Read more
Solutions and products for excavations
- Excavation monitoring: struts, retaining wall, vibration and water in one system
- Vibrating wire strain gauge: strain and strut load, with temperature measurement
- Geotechnical monitoring: monitor excavations, slopes and surroundings
- Construction vibration monitoring: vibration to DIN 4150 with threshold alerts
- Groundwater monitoring: water levels inside and outside the excavation
Specifics
- Measuring section
- Pipe strut: three gauges spaced at 120°, rolled section: at least four
- Reference
- Zero reading before the strut is loaded
- Temperature
- Thermistor in every gauge, the daily cycle becomes visible and can be assessed
- Thresholds
- Warning and alarm level per strut from the design, notification to the site management
Products in use
Sensors installed here
Related solutions & industry
Solutions matching this project
Infrasolute platform
How the readings from this project are evaluated
The readings from this project come together on the Infrasolute platform. There they are checked against the defined limits, shown as trends and interpreted with AI.
Platform modules
Frequently asked questions: Strut monitoring in excavations
How many vibrating wire gauges does a strut need?
When is the zero reading taken?
Why does the strut load change over the day?
Who sets the warning and alarm levels?
What happens if a threshold is exceeded?
Project inquiry
A comparable structure to monitor?
Describe your structure and your question. We recommend the right measuring points and suitable sensors.
Project inquiry
Tell us about your structure
Structure type, location and your question are enough to start. We recommend suitable measuring points and sensors.
[email protected]